Table 31: Calculating Power Budget for a MX480 AC Chassis
Unused Power
1
MaximumSystem Output PowerPower Supply
1721 W3081 WMX480 AC Normal-capacity (low-line)
1840 W3200 WMX480 AC Normal-capacity (high-line)
2141 W3501 WMX480 AC High-capacity (low-line)
2740 W4100 WMX480 AC High-capacity (high-line)
1
For this configuration, output power excluding the cooling system is 1360 W.
Table 32: Calculating Power Budget for a MX480 DC Chassis
Zone 1 Unused
Power
2
Zone 0 Unused
Power
1
Maximum System
Output PowerPower Supply
1290 W240 W3200 WMX480 DC Normal-capacity
2090 W1040 W4800 WMX480 DC High-capacity (DIP=0)
NOTE: The DIP switch position is expected input current;
the correct feeds must be present to obtain the desired
output power.
2290 W1240 W5200 WMX480 DC High-capacity (DIP=1)
NOTE: The DIP switch position is expected input current;
the correct feeds must be present to obtain the desired
output power.
1
For this configuration, output power excluding the cooling system is 1360 W.
2
For this configuration, output power excluding the cooling system is 310 W.
3. Calculate input power. In this step, the input power requirements for the example
configuration are calculated. To do this, divide the total output requirement by the
efficiency of the power supply as shown in Table 33 on page 288.
Table 33: Calculating Input Power Examples
Input Power Requirement
2
Power Supply Efficiency
1
Power Supply
1694 W85 %MX480 AC Normal-capacity (high-line)
1618 W89 %MX480 AC High-capacity (high-line)
1469 W
3
~98 %MX480 DC Normal-capacity
1469 W
3
~98 %MX480 DC High-capacity
Copyright © 2013, Juniper Networks, Inc.288
MX480 3D Universal Edge Router Hardware Guide