CHAPTER 3
Installing ERX Modules
3-10
Figure 3-8 Installing an SRP module
9 Insert the module into the backplane by simultaneously depressing
both ejectors (as shown in Figure 3-7) and exerting forward pressure
on the module.
10 Tighten the module’s captive screws using a Phillips screwdriver.
Turn both screws several times before tightening them completely to
allow the module to sit correctly.
Installing Line Modules and Their I/O Modules
This section describes the procedures for installing line and I/O modules.
Note: Install the I/O module before you install the corresponding line module;
otherwise, the ERX system diagnostics fail, and after the line module has tried to
reboot, its status will be “inactive” when you issue a show version command.
ERX-1400
Ejector in open position